Free Flow H flume Approach Sections

H flume should be used with an approach section which collects the flow and provides a uniform approach to the flume.  The length of the approach section can be varied, the recommended lengths are shown below.

h-appr.bmp (88462 bytes)

H W L
Inches Inches Inches
6 11-3/8 30
9 17-1/16 45
12 22-13/16 60
18 34-3/16 54
24 45-9/16 72
30 57 100
36 68-3/8 108
54 102-9/16 162

 

Free Flow H Flume End Connections

The inlet end of a H flume approach section can be open for use in a channel, or it can be supplied with pipe end connections as follows.

- Grouting or caulking collars which allow the pipe ends to be inserted in the collar              and grouted in place.
- Flat face fiberglass pipe flanges that match standard PVC and iron bolt circles &              patterns.
- Pipe stubs with flexible neoprene couplings which allow quick installation. Watertight              seal is made by using stainless steel band clamps furnished with the couplings.
- Internal expansion couplings that match the I.D. of the coupling.

Typical Inlet End Connections

conn.bmp (33702 bytes)

Caulking Collar      Neoprene Couplings       Flat Face Fiberglass Flanges

Downstream End Connections require the use of a downstream adapter and the downstream pipe connection is usually set much lower than the upstream pipe.  Contact Free Flow for details.

 